Installing the DH.41B option in MOVIDRIVE® MDX61B
Mounting/Installation Instructions
4.6
Installing the DH.41B option in MOVIDRIVE
®
MDX61B
4.7
Installation of the DH.41B option in the MOVIAXIS
®
MDX61B master module
4.7.1
Function description of terminals X5a/X5b (MOVIAXIS
®
master module)
• The connectors X5a and X5b are connected in parallel. In this way, the voltage sup-
ply of the MOVIAXIS
®
master module can be provided from the right to X5b or from
below to X5a. With connection to X5a, further modules can be connected via X5b
(e.g. supply module, axis module). The voltage supply of brake (X5a/b:3, 4) is con-
ducted by the MOVIAXIS
®
master module.
• The MOVI-PLC
®
advanced
DH.41B controller can be supplied by the MOVIAXIS
®
switched mode power supply module (MXS) or from an external voltage supply. For
this purpose, connect X5 between the individual devices.
• If the MOVI-PLC
®
advanced
DH.41B controller is supplied with DC 24 V by the
MOVIAXIS
®
switched-mode power supply module, the function of the MOVI-PLC
®
advanced
DH.41B controller is maintained after disconnection from the power sup-
ply. This is the case if the DC link voltage is maintained or an external DC 24 V supply
of the MOVIAXIS
®
switched-mode power supply unit is present.
NOTE
The MOVI-PLC
®
advanced
DH.41B controller is installed according to chapter "Mount-
ing options for the MOVI-PLC
®
advanced
DH.41B controller". The MOVI-PLC
®
ad-
vanced
DH.41B controller is powered via MOVIDRIVE
®
MDX61B. A separate voltage
supply is only required for the binary inputs and outputs (connector X31).
NOTE
The MOVI-PLC
®
advanced
DH.41B controller is installed according to chapter "Mount-
ing options for the MOVI-PLC
®
advanced
DH.41B controller". To wire the system bus,
connect connector X33 (CAN1) or X32 (CAN2) of MOVI-PLC
®
advanced
DH.41B with
connector X9 (MOVIAXIS
®
supply module signalizing bus or of a MOVIAXIS
®
axis
module) or with connector X12 (CAN2 bus of a MOVIAXIS
®
axis module). The
MOVIAXIS
®
master module also provides further connections as described below.
MOVIAXIS
®
master
module MXM
Designation
Terminal
Function
59233AXX
X5b connector
X5b:1
X5b:2
X5b:3
X5b:4
DC 24 V
E
DGND
DC 24 V
B
BGND
Voltage supply for control electronics
Reference potential of control electron-
ics
Brake voltage supply
Reference potential for brake connec-
tion
X5a connector
X5a:1
X5a:2
X5a:3
X5a:4
DC 24 V
E
DGND
DC 24 V
B
BGND
Voltage supply for control electronics
Reference potential of control electron-
ics
Brake voltage supply
Reference potential for brake connec-
tion
X5b
2
1
3
4
2
1
3
4
X5a