112
Operating Instructions – Electronic Motor DRC.-..-DAC
8
Overview of power section parameters
Parameters
Temperatures
8399.0
Heat sink temperature t-3
[°C]
1 digit = 1 °C
10070.4
Motor temperature t-3
[°C]
1 digit = 10
−
6
°C
Power section parameters \ Display values \ Error memory 0-4 \ Error memory t-4
Error status
8370.0
Error t-4 error code
[Text]
10072.5
Error t-4 suberror code
[Text]
8887.0
Error t-4 internal
[Text]
10404.10
Source of error t-4
[Text]
Actual drive values
8405.0
Actual speed t-4
[rpm]
1 digit = 0.001 rpm
8410.0
Apparent output current t-4
[%]
1 digit = 0.001 %
8415.0
Active output current t-4
[%]
1 digit = 0.001 %
8420.0
Unit utilization t-4
[%]
1 digit = 0.001 %
8445.0
Motor utilization t-4
[%]
1 digit = 0.001 %
8425.0
DC link voltage t-4
[V]
1 digit = 0.001 V
Unit status
8395.0
Power section status t-4
[Text]
8430.0
Operating hours t-4
[h]
1 digit = 1 min = 1/60 h
8435.0
Enable hours t-4
[h]
1 digit = 1 min = 1/60 h
10083.5
Work t-4
[kWh]
1 digit = 1Ws = 1/3600000
Temperatures
8400.0
Heat sink temperature t-4
[°C]
1 digit = 1 °C
10070.5
Motor temperature t-4
[°C]
1 digit = 10
−
6
°C
Index
Parameter name
MOVITOOLS
®
MotionStudio
Display
(Range / factory setting)
MOVILINK
®
scaling
00
I