Operating Instructions – Electronic Motor DRC.-..-DAC
115
8
Overview of power section parameters
Parameters
Terminal assign-
ment
Index
Parameter name
MOVITOOLS
®
MotionStudio
Display
(Range / factory setting)
MOVILINK
®
scaling
Power section parameters \ terminal assignment \ binary outputs
8349.0, bit 1
Binary output DO01 status (signal relay K1)
[Bit field]
8350.0
Binary output DO01 function (signal relay
K1)
•
0 = No function
•
1 = /Fault
•
2 = Ready
•
3 = Output stage ON
•
4 = Rotating field ON
•
5 = Brake released
•
6 = Brake applied
•
7 = Motor standstill
•
8 = Reserved
•
9 = Speed reference signal
•
10 = Speed reference signal
•
11 = Setpoint-actual value comparison signal
•
12 = Current reference signal
•
13 = Imax signal
•
14 = /Warning motor utilization 1
•
19 = IPOS in position
•
20 = IPOS referenced
•
21 = IPOS output
•
22 = /IPOS fault
•
27 = STO – safe torque off
•
34 = Process data bit
00