124
Operating Instructions – Electronic Motor DRC.-..-DAC
8
Description of command PCB parameters
Parameters
Ramp t15 up index
10504.1
Only in conjunction with AS-Interface double slave GLK31A:
Use this parameter to set acceleration ramp "t15 up" (depending on which function
module is active).
• Unit: [s]
• Setting range: 0 – 1 – 60 s
The ramp times refer to a setpoint step change of
∆
n = 3000 rpm.
Ramp t15 down
index 10504.11
Only in conjunction with AS-Interface double slave GLK31A:
Use this parameter to set deceleration ramp "t15 down" (depending on which function
module is active).
• Unit: [s]
• Setting range: 0 – 1 – 60 s
The ramp times refer to a setpoint step change of
∆
n = 3000 rpm.
Ramp t16 up index
10475.2
Only in conjunction with AS-Interface double slave GLK31A:
Use this parameter to set acceleration ramp "t16 up" (depending on which function
module is active).
• Unit: [s]
• Setting range: 0 – 1 – 60 s
The ramp times refer to a setpoint step change of
∆
n = 3000 rpm.
Ramp t16 down
index 10475.1
Only in conjunction with AS-Interface double slave GLK31A:
Use this parameter to set deceleration ramp "t16 down" (depending on which function
module is active).
• Unit: [s]
• Setting range: 0 – 1 – 60 s
The ramp times refer to a setpoint step change of
∆
n = 3000 rpm.
00
I