Operating Instructions – Electronic Motor DRC.-..-DAC
129
8
Description of power section parameters
Parameters
Power section parameters \ display values \ binary outputs
Binary output
DO01
index 8349.0, bit 1
The parameter indicates the present state of binary output DO01 (e.g. signal relay K1)
of the basic unit.
Binary output
DO01
index 8350.0
The parameter indicates the current function assignment of binary output DO01 (e.g.
signal relay K1) of the basic unit.
Power section parameters \ display values \ unit data
Unit series index
9701.10
The parameter indicates the unit series, for example "DRC".
Variant ID index
9701.11
The parameter indicates the unit generation, for example "B".
Unit name
index 9701.1,
9701.2, 9701.3,
9701.4, 9701.5
The parameter indicates the type designation of the power section.
Unit variant index
10204.2
The parameter indicates the DRC installation technology, e.g.:
• DBC = Direct Binary Communication
• DAC = Direct AS-Interface Communication
• DSC = Direct SBus Communication
• SNI = Single Line Network Installation
Unit signature
index 9823.1,
9823.2, 9823.3,
9823.4, 9823.5
The parameter is used to indicate and enter the unit signature. This parameter is used
to assign a name to the power section so you can identify it in the hardware tree or in
other visualization elements.
Nominal unit
current (rms)
index 8361.0
The parameter indicates the nominal unit current (rms value).
• Unit: [mA]
Motor size
index 10079.9
The parameter indicates the size of the DRC drive unit.
Nominal motor
torque
index 9610.1
The parameter indicates the available continuous torque of the motor.
• Unit: [Nm]
Basic unit firmware
index 9701.30
The parameter indicates the part number of the firmware used in the power section.
Status of basic unit
firmware
index 9701.31
The parameter indicates the status of the firmware used in the power section.
00
I