130
Operating Instructions – Electronic Motor DRC.-..-DAC
8
Description of power section parameters
Parameters
Power section parameters \ display values \ gear unit data
Gear unit ratio
"numerator"
index 10079.3
The parameter indicates the gear ratio tooth numbers. This allows for representing the
gear ratio in whole numbers.
Gear unit ratio
"denominator"
index 10079.4
The parameter indicates the gear ratio tooth numbers. This allows for representing the
gear ratio in whole numbers.
Gear ratio
The parameter indicates the gear ratio.
Power section parameters \ Display values \ Error memory 0-4 \ Error memory t-0–4
There are 5 error memories (t-0 – t-4). The errors are stored in a chronological sequence
with the most recent error event being stored in error memory t-0. If there are more than
5 errors, the error event of longest standing, stored in t-4, is deleted.
Programmable error responses: see chapter "Unit functions/error monitoring".
The following information available at the time of the error is stored and can be used for
detailed diagnostics:
• State of binary inputs / binary outputs
• Actual speed
• Apparent output current
• Active current
• Unit utilization
• Motor utilization
• DC link voltage
• Power section status
• Operating hours
• Enable hours
• Work
• Heat sink temperature
• Motor temperature
• Electronics temperature
Error t-0 – 4 error
code index 8366.0,
8367.0, 8368.0,
8369.0, 8370.0
The parameter shows the error group with error number and in plain text.
00