Operating Instructions – Electronic Motor DRC.-..-DAC
191
11
Description of status and operating displays
Service
Red
Steady light
Error 40
Boot synchronization error
Error 41
Watchdog option error
Error 116
MOVI-PLC
®
timeout
Error 119
Safety error
Red
Flashing slowly
Error 08
Speed monitoring error
Error 26
External terminal error
Error 30
Emergency stop timeout error
Error 15
Encoder error
Error 16
Incorrect startup
Error 45
Initialization error
Incorrect motor/inverter assignment
Error 50
Internal voltage supply too low
Errors 17, 18, 37, 53
CPU error
Error 25
NV memory error
Error 27, 29
"Limit switch" error
Error 39
"Reference travel" error
Error 42
Positioning lag error
Error 94
Checksum error
Error 97
Parameter transmission error
Errors 10, 32, 77
IPOS error
Error 123
Positioning interruption error
Red
2x flashing, break
Error 07
DC link voltage too high
Red
3x flashing, break
Error 01
Overcurrent in output stage
Error 11
Overtemperature of heat sink or electronics
Red
4x flashing, break
Error 31
TF trip
Error 44
Ixt utilization/UL monitoring
Error 52
Machine control error
Red
5x flashing, break
Error 89
Only in conjunction with DRC electronic motor:
Overtemperature in brake
Red
6x flashing, break
Error 06
Line phase failure
DRIVE LED
LED color
LED status
Operating state
Description