Operating Instructions – Electronic Motor DRC.-..-DAC
55
5
Plug connectors
Electrical Installation
5.7.3
Plug connector positions
The following figure shows the possible plug connector positions. A difference is made
between plug connectors with selectable position and plug connectors with fixed
position:
Plug connector
Color
Position Location
X5132: Digital inputs/outputs
–
As
required
X, 2 or 3,
not together with X1203_1, X1203_2
X5502: STO – IN
Orange
Fixed
3 (left)
X5503: STO – OUT
Orange
Fixed
3 (right)
X4271: AS-Interface communication
interface
1)
1) Standard scope of delivery
Yellow
Fixed
X
X5011: AS-Interface sensors
1)
Black
Fixed
2
X1203_1: AC 400 V connection
2)
2) Plug connector X1203_1 is also available separately (i.e. without plug connector X1203_2).
Black
As
required
X, 2 or 3, not together with X5132
X1203_2: AC 400 V connection
Black
As
required
X, 2 or 3, not together with X5132
[1] Pressure compensation
3)
3) Only in conjunction with the optional design for use in wet areas (with MOVIGEAR
®
) / ASEPTIC design
(with DRC).
–
Fixed
Depends on mounting position
9007201700801803
X5132
X5132
X5132
X1203_1
X1203_1
X1203_1
X1203_2
X1203_2
X1203_2
[1]
X5502
X5503
X4271
X5011
[1]
X
2
3