Operating Instructions – Electronic Motor DRC.-..-DAC
61
5
Assignment of optional plug connectors
Electrical Installation
Connection of
cables with open
end
The following table shows the conductor assignment of the cable with the following part
number:
1 812 747 9, 1 813 396 7, 1 812 749 5 and 1 813 398 3
Part number 1 812 748 7
Variable
4 mm
2
AC 500 V
M23, coding ring:
Black
M23, coding ring:
Black
Part number 1 813 397 5
Halogen-free
Variable
4 mm
2
AC 500 V
M23, coding ring:
Black
M23, coding ring:
Black
Part number 1 812 749 5
Variable
4 mm
2
AC 500 V
Open
M23, coding ring:
Black
Part number 1 813 398 3
Halogen-free
Variable
4 mm
2
AC 500 V
Open
M23, coding ring:
Black
Connection cable
Length/
installa-
tion type
Cable
cross
section
Operating
voltage
Signal name
Core color/designation
L1
Black / 1
L2
Black / 2
L3
Black / 3
PE
Green/yellow