80
Operating Instructions – Electronic Motor DRC.-..-DAC
6
Startup with binary slave GLK30A in "Expert mode"
Startup
6.7
Startup with binary slave GLK30A in "Expert mode"
6.7.1
Startup steps
In Expert mode, individual parameters can be used in addition to the basic functionality
of the DRC drive unit.
1. It is essential that you observe the startup instructions.
2. Disconnect all components from the voltage supply and use an external disconnect-
ing device to avoid unintentional re-connection.
3. Make sure that the DRC drive unit is connected properly. Observe chapter "Electrical
Installation".
4. Start up the unit in "Easy" mode.
5. Set DIP switch S2/1 to ON to activate "Expert" mode.
NOTICE
Damage to the DIP switches caused by using unsuitable tools.
Possible damage to property.
• To set the DIP switches, use only suitable tools, such as a slotted screwdriver with
a blade width of no more than 3 mm.
• The force used for setting the DIP switches must not exceed 5 N.
6. Connect the PC to the DRC inverter.
7. Connect the DRC inverter to the voltage supply.
8. Start MOVITOOLS
®
MotionStudio and integrate the DRC inverter.
9. Specify the parameters you want to change.
INFORMATION
• "Expert" startup is only necessary if parameters are to be set during startup.
• The following chapter describes the preparations made on the DRC inverter for
activating Expert mode and an example for fine-tuning parameters.
• The chapter "Parameterization and diagnostics" describes how to integrate the
DRC inverter in MotionStudio and provides an overview of all parameters with a
detailed description.
2444784139
ON
DIP
1 2 3 4
S2
DIP switch S2/1 = ON
Expert mode
00
I