180
Operating Instructions – Electronic Motor DRC.-..-DAC
10
Manual operation with MOVITOOLS
®
MotionStudio
Operation
Brake
On DRC drive units with a brake, you can release the brake even without drive enable
signal by enabling the "Brake release" checkbox [8].
10.1.3 Reset in manual mode
If an error occurs at the DRC inverter, you can reset the error by clicking on the [Reset]
button [10].
10.1.4 Timeout monitoring in manual mode
Timeout monitoring is active during manual mode to prevent uncontrolled operation of
the DRC drive unit in case of communication problems.
If communication between MOVITOOLS
®
MotionStudio and the DRC inverter is
interrupted longer than this timeout interval, the enable signal for the DRC drive unit is
withdrawn. Manual mode remains active.