Operating Instructions – Electronic Motor DRC.-..-DAC
23
4
Installation requirements
Mechanical Installation
4.3
Installation requirements
Check that the following conditions have been met:
• The entries on the nameplate of the DRC unit match the voltage supply system.
• The drive is undamaged (no damage caused by transportation or storage)
• Ambient temperature according to the operating instructions, nameplate and
lubricant table in chapter "Technical data and dimension sheets / Lubricants".
• The drive must not be assembled in the following ambient conditions:
– Potentially-explosive atmosphere
– Oils
– Acids
– Gases
– Vapors
– Radiation
• For special designs: The drive is designed in accordance with the actual ambient
conditions.
• You must clean the output shafts and flange surfaces thoroughly to ensure they are
free of anti-corrosion agents, contamination or similar. Use a commercially available
solvent. Do not expose the sealing lips of the oil seals to the solvent – damage to the
material.
• When the drive is installed in abrasive ambient conditions, protect the output end oil
seals against wear.