48
Operating Instructions – Electronic Motor DRC.-..-DAC
5
Connecting DRC drive units
Electrical Installation
5.4
Connecting DRC drive units
WARNING
No safe disconnection of the DRC drive unit.
Severe or fatal injuries.
• Do not use the 24 V output (terminals 4, 5, 14, 15) for safety-related applications
with DRC drive units.
• You may only jumper the STO input with 24 V when the DRC drive unit need not
fulfill any safety function.
4729674123
Local mode
Automatic mode active
Local mode active
Terminal functions
CW/stop and CCW/stop:
Direction of rotation
CW
active
Direction of rotation
CCW
active
Functions of terminals f1/f2:
Setpoint
f1
active
Setpoint
f2
active
[1] See chapter "Terminal assignment"
[2] Integrated 24 V supply
[3] CW/stop
[4] CCW/stop
[5] Setpoint changeover f1/f2
[6] Automatic mode/local mode
[7] Signal relay
(contact closed = ready for operation)
[8] Assignment see chapter "Plug connector
assignment"
[9] Braking resistor connection
L1
L2
L3
PE
K11
F11/F12/F13
L1 IN
1
L2 IN
2
BW
BW
DRC.-...-DAC
[3]
[4]
[5]
[7]
13 K1b
3 K1a
2 STO
̶ IN
1 STO + IN
12 STO
̶ OUT
11 STO + OUT
23 DI02 L
22 DI01 R
5 0V24_O
4 24V_O
15 0V24_O
14 24V_O
[6]
[2]
[2]
24 DI03 f1/f2
25 DI04 Auto/local
L3 IN
1
2
[9]
3
L1 OUT
11
L2 OUT
12
L3 OUT
13
Control
terminals [1]
Line terminals [1]
Braking resistor
terminals [1]
X2
X7
X5
[8]
Sensor input
connection
[8]
2
1
4
3
AS-Interface
connection
1
4
3
2
5
14 24V_O
23 DI02 L
22 DI01 R
24 DI03 f1/f2
25 DI04 Auto/local
16 24V_O
14 DI02 L
4 DI01 R
5 DI03 f1/f2
15 DI04 Auto/local
22 DI01 R
23 DI02 L
14 24V_O
22 DI01 R
23 DI02 L
14 24V_O
22 DI01 R
23 DI02 L
14 24V_O
24 DI03
f1/f2
22 DI01 R
23 DI02 L
14 24V_O
24 DI03
f1/f2