Operating Instructions – MOVIDRIVE® MDR60A/61B
69
6
Explanation of the parameters
MDR61B1600/2500 – Parameters
• d: PRECHARGE
• F: ERROR
• t: WAITING FOR DATA
• U: STO
→
X17 signal jumpers not installed
P012 Fault status
Error number and error in plain text. The error number also appears on the 7-segment
display of the regenerative power supply.
P014 Heat sink
temperature
Heat sink temperature of the regenerative power supply in the range
−
40 – +125 °C.
P015 Operating
hours
Total number of hours for which the regenerative power supply unit has been connected
to the supply system or an external DC 24 V supply. Storage cycle every 1 min.
P016 Enable hours
Total number of hours for which the regenerative power supply was in ENABLE operat-
ing state; storage cycle every 1 min.
P017 Work
Total of the active electrical energy the regenerative power supply has consumed; stor-
age cycle every 1 min.
P03x Binary inputs of basic unit
P030 – P032
Binary inputs
DI00 – DI02
Displays the current status of input terminals DI00 – DI02 and the current function as-
signment.
Binary input DI00 is always assigned with controller inhibit.
Menu selection see
P60x Binary inputs of basic unit
.
P039 Binary inputs
DI00 – DI07
Displays the standard binary inputs DI00 to DI07 in this sequence.
P05x Binary outputs of basic unit
P051 – P055
Binary outputs
DO01 – DO05
Displays the current state of the binary output on the basic unit with the current function
assignment.
Menu selection see
P62x Binary outputs of basic unit
.
P059 Binary out-
puts DO01 – DO05
Displays the binary outputs DO01 – DO05 in this sequence.
P07x Unit data
P070 Unit type
Displays the complete designation of the unit, e.g. MDR61B2500-503.
P071 nominal out-
put current
Displays the r.m.s. value of the nominal inverter current.
P072 Option/
encoder slot
The display shows "MDR" for the line voltage measurement pcb that is currently plugged
into the encoder slot.
P076 Basic unit
firmware
Displays the program version of the firmware used in the basic unit.
P
i
f
kVA
Hz
n