Operating Instructions – MOVIAXIS® MX Multi-Axis Servo Inverter
105
5
Supply module settings for a CAN-based system bus
Startup
Connections and PC diagnostics
The maximum permitted cable length between terminating resistor and supply module
is 5 m.
For more information on communication between PC and the MOVIAXIS
®
system, refer
to page 111.
NOTES
CAN connections should only be implemented in the control cabinet to avoid any dif-
ference of potential.
59095axx
Figure 60: CAN cable length
[1]
Connection cable between PC and CAN interface on the supply module. The connection cable con-
sists of the USB-CAN interface [2] and the cable with integrated terminating resistor [3].
[2]
USB-CAN interface
[3]
Cable with integrated terminating resistor (120
Ω
between CAN_H
and CAN_L)
MXP
CAN1
max. 5 m
[2]
[3]
[1]
NOTES
Observe the notes of the cable manufacturer on CAN suitability when selecting the
cable.
0