110
Operating Instructions – MOVIAXIS® MX Multi-Axis Servo Inverter
5
CAN2 bus information and settings
Startup
Bus terminating resistors for CAN2 bus connection:
The signal bus connection includes the CAN2 connection between supply module and
axis module. The CAN2 bus requires a terminating resistor.
The following figure shows the diagram of possible combinations for CAN communica-
tion and the respective position of the terminating resistor (supply module accessory).
For more information on communication between PC and the MOVIAXIS
®
system, refer
to page 111.
62483aen
Figure 67: Communication via CAN2 at an axis module
[1]
Connection cable between PC and CAN interface on the axis module. The connection cable consists
of the USB-CAN interface [2] and the cable with integrated terminating resistor [3].
[2]
USB-CAN interface
[3]
Cable with integrated terminating resistor (120
Ω
between CAN_H
and CAN_L)
MXP
MXA
1
The terminating resistor
must be activated
at the CAN2 unit
connection.
CAN2
Terminating
resistor
6
7
8
9
5
1
2
3
4
[2]
[3]
[1]
NOTES
Install terminating resistor.
The terminating resistor in the last axis module of the axis system must be activated,
see page 109.