168
Operating Instructions – MOVIAXIS® MX Multi-Axis Servo Inverter
6
Operating displays and errors of MXA axis module
Operation
19
Process data
error
Process data are not valid
Output stage
inhibit
System is
blocked
System restart
Yes
Ready = 0
Malfunction
= 0
01
Process data: Negative maximum
torque indicated
02
Process data: Positive minimum
torque indicated
03
Process data: Negative motor torque
limit indicated
04
Process data: Negative regenerative
torque limit indicated
05
Process data: Torque limit for quad-
rant 1 is negative
06
Process data: Torque limit for quad-
rant 2 is negative
07
Process data: Torque limit for quad-
rant 3 is negative
08
Process data: Torque limit for quad-
rant 4 is negative
09
Torque control: Maximum speed <
minimum speed
10
Position control: Maximum speed
value < 0
11
Position control: Maximum speed < 0
12
Position control: Minimum speed > 0
13
Process data: Enter negative acceler-
ation
14
Process data: Enter negative delay
15
Process data: Enter negative jerk
16
Combination of FCB number and
FCB instance does not exist
17
Target position outside limit switch
range
20
Setpoint devia-
tion electronic
cam
The preset setpoint deviation limit in
electronic cam mode was exceeded
Output stage
inhibit
System is
waiting
Warm start
Yes
Ready = 1
Malfunction
= 0
01
CAM: Setpoint deviation electronic
cam
21
Setpoint devia-
tion dual drive
The preset setpoint deviation limit in
dual drive mode "Engel" was
exceeded
Output stage
inhibit
System is
waiting
Warm start
Yes
Ready = 1
Malfunction
= 0
01
FCB dual drive: Setpoint deviation in
conditioning phase
02
FCB dual drive: Setpoint deviation in
standard operation
Error
code
Error message Sub
error
code
Possible reason for error
Error response
(P = programma-
ble,
D = default
response)
Final error
status /
Reset type
Save
as
History
Message
binary out-
puts (valid
for default
response)