172
Operating Instructions – MOVIAXIS® MX Multi-Axis Servo Inverter
6
Operating displays and errors of MXA axis module
Operation
53
Error
"CRC Flash“
A CRC error occurred during check of
the program code by Flash in Code
RAM or Resolver DSP.
Output stage
inhibit
System is
blocked
System restart
Yes
Ready = 0
Malfunction
= 0
01
CRC error in Flash EEPROM section
"Initial Boot Loader"
54
Unassigned
55
Error "FPGA
Configuration“
Internal error in logic component
block (FPGA)
Output stage
inhibit
System
locked / CPU
reset
Yes
Ready = 0
Malfunction
= 0
56
Error "External
RAM“
Internal error in external RAM block
Output stage
inhibit
System
locked / CPU
reset
Yes
Ready = 0
Malfunction
= 0
01
Asynchronous DRAM read&write
check error
57
Error "TTL
encoder“
Error in TTL encoder
Output stage
inhibit
System is
blocked
System restart
Yes
Ready = 0
Malfunction
= 0
01
TTL sensor: Open circuit
02
TTL sensor: Emulation error (exces-
sive speed)
19
TTL sensor: Non-permissible angle
during calibration
512
TTL sensor: Amplitude control has
failed
513
TTL sensor: EPLD reports error
58
Error
"Sine/cosine
encoder“
Error in sine/cosine encoder evalua-
tion
Output stage
inhibit
System is
blocked
System restart
Yes
Ready = 0
Malfunction
= 0
01
Sin/cos encoder: Open circuit detec-
tion
02
Sin/cos encoder: Emulation error
(excessive speed)
19
Sin/cos encoder: Non-permissible
angle during calibration
512
Sin/cos encoder: Amplitude control
has failed
514
Sin/cos encoder: Quadrant control
has failed
Error
code
Error message Sub
error
code
Possible reason for error
Error response
(P = programma-
ble,
D = default
response)
Final error
status /
Reset type
Save
as
History
Message
binary out-
puts (valid
for default
response)
Summary of Contents for MOVIAXIS MX
Page 2: ...SEW EURODRIVE Driving the world...
Page 210: ......