Operating Instructions – MOVIAXIS® MX Multi-Axis Servo Inverter
175
6
Operating displays and errors of MXA axis module
Operation
69
Error "Prewarn-
ing motor over-
temperature"
Motor temperature has exceeded the
adjustable prewarning threshold
No response, dis-
play only
---------
Yes
Ready = 1
Malfunction
= 1
01
Thermal motor protection: Prewarn-
ing triggered by KTY temperature
02
Thermal motor protection: Prewarn-
ing triggered by synchronous motor
model temperature
03
Thermal motor protection: Warning
threshold l2t model exceeded
70
Error 'Error mes-
sage word 0'
The error message of an unknown
device was detected in the error mes-
sage word
No response, dis-
play only
---------
Yes
01
Message error control word 0
71
Error 'Error mes-
sage word 1'
The error message of an unknown
device was detected in the error mes-
sage word
No response, dis-
play only
---------
Yes
01
Message error control word 1
72
Error 'Error mes-
sage word 2'
The error message of an unknown
device was detected in the error mes-
sage word
No response, dis-
play only
---------
Yes
01
Message error control word 2
73
Error 'Error mes-
sage word 3'
The error message of an unknown
device was detected in the error mes-
sage word
No response, dis-
play only
---------
Yes
01
Message error control word 3
74
Error 'Error mes-
sage word 4'
The error message of an unknown
device was detected in the error mes-
sage word
No response, dis-
play only
---------
01
Message error control word 4
75
Error 'Error mes-
sage word 5'
The error message of an unknown
device was detected in the error mes-
sage word
No response, dis-
play only
---------
Yes
01
Message error control word 5
76
Error: "Intelligent
option"
MOVI-PLC error
No response, dis-
play only
---------
Yes
77
Unassigned
78
Unassigned
79
Unassigned
80
Unassigned
81
Error "DC link
overcurrent SM“
The DC link current in the SM has
exceeded the maximum limit of 250%
I
rated
Output stage
inhibit
System is
waiting
Warm start
Yes
Ready = 1
Malfunction
= 0
01
SM: DC link current too high
82
Prewarning "I²xt
monitoring SM“
Utilization of the SM has reached the
prewarning level
No response (D),
(P)
--------
Yes
Ready = 1
Malfunction
= 1
01
SM: Pre-warning Ixt utilization
83
Error "I²xt moni-
toring SM“
Utilization of the SM has reached or
exceeded the cut-off threshold
Shutdown with
emergency stop
delay (D)
System is
waiting
Warm start
Yes
Ready = 1
Malfunction
= 0
01
SM: Error Ixt utilization
Error
code
Error message Sub
error
code
Possible reason for error
Error response
(P = programma-
ble,
D = default
response)
Final error
status /
Reset type
Save
as
History
Message
binary out-
puts (valid
for default
response)
Summary of Contents for MOVIAXIS MX