Technical data for line filter and line chokes
Technical Data
8.12 Technical data for line filter and line chokes
Line filter
Line choke
8.13 Safety technology (safe stop)
Line filter type
1)
NF018-503
NF048-503
NF085-503
NF150-503
Part number
827 413 4
827 117 8
827 415 0
827 417 7
Power supply module
Size 1
Size 2
BG3
BG3
Rated voltage
U
N
V
AC
3 x 500 +10 %, 50/60 Hz
Rated current
I
N
A
AC
18
48
85
150
Power loss at I
N
P
V
W
12
22
35
90
Earth-leakage current at U
N
mA
< 25
< 40
< 30
< 30
Ambient temperature
ϑ
U
° C
–25 ... +40
Degree of protection
IP20 (EN 60529)
Connections L1-L3/L1’-L3’
PE
mm
2
4
M5 stud
10
M5/M6 stud
35
M8
50
M10
NF...type line filter
2)
1) Unit
2) SEW-EURODRIVE will provide a certificate upon request.
Line choke type
1)
ND020-013
ND045-013
ND085-013
ND150-013
Part number
826 012 5
826 013 3
826 014 1
825 548 2
Power supply module
Size 1
Size 2
BG3
BG3
Rated voltage
U
N
V
AC
3 x 500 +10 %, 50/60 Hz
Rated current
I
N
A
AC
20
45
85
150
Power loss at I
N
P
V
W
10
15
25
62
Inductance
L
N
mH
0.1
--
--
--
Ambient temperature
ϑ
U
° C
–25 ... +40
Degree of protection
IP00 (EN 60529)
Connections L1-L3/L1’-L3’
PE
mm
2
4
Terminal strips
10
Terminal strips
35
Terminal strips
M10 stud
PE: M8 stud
1) Unit
NOTES
It is essential to observe the information on this topic in the following publications:
• "Safe Disconnection for MOVIAXIS
®
– Conditions".
• "Safe Disconnection for MOVIAXIS
®
– Applications".
P
i
f
kVA
Hz
n
Summary of Contents for MOVIAXIS MX
Page 2: ...SEW EURODRIVE Driving the world...
Page 210: ......
Page 211: ...SEW EURODRIVE Driving the world...