24
Operating Instructions – MOVIAXIS® MX Multi-Axis Servo Inverter
3
Unit design of MOVIAXIS® MXP power supply module
Unit Design
MOVIAXIS
®
MXP supply module size 2
64525axx
Figure 12: Unit design of MOVIAXIS
®
MXP power supply module size 2
A
View from top
B
View from front
C
View from bottom
[1]
Signaling bus
X9a: Input, green plug on cable
X9b: Output, red plug on cable
[2]
Electronics shield clamps
[13]
X3: Braking resistor con-
nection
[3]
C, E: DIP switches
- C: CAN-based system bus
- E: EtherCAT-based system bus
[14]
X1: Mains connection
[4]
X12: System bus CAN
[5]
S1, S2: DIP switch for CAN baud rate
[6]
S3, S4: Axis address switch
[7]
Standby display (Power)
[8]
2 x 7-segment display
[9]
X5a, X5b: 24 V voltage supply
[10]
X4: DC link connection
[11]
Housing grounding point
[12]
Power shield clamp
B
A
[1]
X9a
X9b
[4]
[7]
[8]
[9]
[11]
[5]
[6]
[10]
[3]
[13]
C
[2]
[14]
[12]
Summary of Contents for MOVIAXIS MX