4
Safety requirements
Encoder requirements
Manual – MOVISAFE
®
CS..A Safety Card
31
Motor sizes
Encoders
Part number
with
without
Connection cover
DR..160 – DR..280
DRN132M –
DRN280
EG7S
13642952
13642782
AG7W
13643924
13643886
Motor sizes
Encoders
Part number
DR..71 – DR..132
DRN80 – DRN132S
EI7C FS
Ordering with part number not possible
4.6.2
Safety encoders on the EDR.., EDRN.. explosion-proof AC motor.
The safety encoders described below are designated for use with EDR.., EDRN.. mo-
tors. It is not permitted to mount them to other motors.
Motor sizes
Encoders
Part number
with
without
Connection cover
EDR..71 –
EDR..132
EDRN80 –
EDRN132S
ES7S
13642898
13642715
AS7W
13643916
13643878
EDR..160 –
EDR..280
EDRN132M –
EDRN280
EG7S
13642952
13642782
AG7W
13643924
13643886
4.6.3
Safety encoders on the CMP/CMPZ synchronous servomotor
The safety encoders described below are designated for use with the CMP.. and
CMPZ.. synchronous servo motors. It is not permitted to mount them to other motors.
•
AK0H (part number 13356615)
Permitted for: CMP40 – CMP112S/M, CMPZ71 – CMPZ100
•
AK1H (part number 13410547)
Permitted for: CMP50 – CMP112L/H/E, CMPZ71 – CMPZ100
In order to implement a drive safety function with the AK0H or AK1H encoder, the mo-
tor must be started with the control mode CFC.
In addition, the following inverter settings are also recommended:
•
Activation of lag error monitoring
•
Activation of speed monitoring
•
Activation of encoder monitoring
24842532/EN – 04/2018