13
Technical data
Safe digital inputs
Manual – MOVISAFE
®
CS..A Safety Card
104
13.3
Safe digital inputs
F-DI00 – F-DI03
Value/description
Properties
DC 24 V input pursuant to EN 61131-2, type 3
Signal level
•
Logic "0" = LOW input:
≤ 5 V or ≤ 1.5 mA
•
Logic "1" = HIGH input:
≥ 11 V and ≥ 2 mA
Reference ground
GND
Power demand (typical)
0.21 W at DC 24 V
Input current
≤ 15 mA
Input resistance
≤ 4 kΩ at DC 24 V
Input filter time, parameterizable
4 ms – 250 ms
Permitted cable length
30 m
Error response time with single-pole
connection
No greater than the response time without
error.
Edge steepness of input signal
> 120 V/s
Input capacitance
< 500 pF
24842532/EN – 04/2018