13
Technical data
Sensor supply
Manual – MOVISAFE
®
CS..A Safety Card
105
13.4
Sensor supply
F-SS0, F-SS1
Value/description
Properties
•
DC 24 V output pursuant to EN 61131-2
•
Short circuit and overload protection
•
No galvanic isolation
Rated current
150 mA
Inrush current (≤ 10 ms)
300 mA
Short-circuit protection
1.2 A
Internal voltage drop
< DC 1.3 V
Pulsed voltage supply (if activated)
•
2 ms open (LOW)
•
Period duration, pulsed voltage supply:
8 ms
Permitted cable length
30 m (per sensor)
Leakage current (F-SSx blocked)
< 0.1 mA
13.5
Safe digital outputs
F-DO00_P/M, F-DO01_P/M
Value/description
Properties
•
DC 24 V output pursuant to EN 61131-2
•
Short circuit and overload protection
Rated current
150 mA
Inrush current (≤ 10 ms)
300 mA
Leakage current (F-DOx blocked)
< 0.1 mA
Maximum switching frequency
10 Hz
Overload protection
210 mA
Minimum current for wire break
monitoring
15 mA
Permitted cable length
30 m
Load capacitance (max. test pulse
duration)
≤ 300 nF
Load capacitance (1 ms test pulse
duration)
50 nF
Capacitance to GND/PE (sourcing
output only)
≤ 10 nF
Load capacitance with diode de-
coupling
≤ 12 µF
Load inductance
≤ 100 µH
Load inductance with freewheeling
diode
≤ 40 H
Minimum load resistance
> 130 Ω
24842532/EN – 04/2018