8
Electrical installation
Safe disconnection
Manual – MOVISAFE
®
CS..A Safety Card
45
8.3.2
Terminal assignment
Description
LED/
Terminal
Function
F-RUN LED
F-ERR LED
F-RUN LED
F-ERR LED
The LEDs indicate the respective status of
the CS..A option (see chapter "Dia-
gnostics").
XS: Slot for safety key
XS
Slot for safety key.
X17 (D-sub DA-15):
Connecting
non-safe encoders
(with
CSS31A and CSB31A only)
X17:1 – 15
Assignment according to the
non-safe en-
coder
connected
(see manual "MOVIDRIVE
®
modular,
MOVIDRIVE
®
system – multi-encoder card
CES11A").
X60: Connection of digital inputs (plug-
in spring-loaded terminals)
X60:1 F-DI00
Safe digital input F-DI00.
X60:2 F-DI01
Safe digital input F-DI01.
X60:3 GND
Reference potential for safe inputs/outputs.
X60:4 GND
Reference potential for safe inputs/outputs.
X60:5 F-DI02
Safe digital input F-DI02.
X60:6 F-DI03
Safe digital input F-DI03.
X60:7 GND
Reference potential for safe inputs/outputs.
X60:8 GND
Reference potential for safe inputs/outputs.
X60:9 F-SS0
DC 24 V sensor voltage supply for safe di-
gital inputs F-DI00 and F-DI02.
X60:10 F-SS1
DC 24 V sensor voltage supply for safe di-
gital inputs F-DI01 and F-DI03.
X60:11 F-DO00_M
Safe digital output F-DO00_M (not with
CSB21A).
X60:12 F-DO00_P
Safe digital output F-DO00_P (not with
CSB21A).
X60:13 F-DO01_M
Safe digital output F-DO01_M (not with
CSB21A).
X60:14 F-DO01_P
Safe digital output F-DO01_P (not with
CSB21A).
8.4
Safe disconnection
The jumper plug X6 must be removed if a MOVISAFE
®
CS..A safety card is installed
in the MOVIDRIVE
®
modular/system. No other voltage may be connected to the in-
verter as well.
8.5
Safe digital inputs (F-DI.)
The safe digital inputs (F-DI.) are connected at terminal X60. The following sections
explain and describe the permitted connection options.
24842532/EN – 04/2018