9
Startup
Restoring the delivery state
Manual – MOVISAFE
®
CS..A Safety Card
69
9.8.4
Confirming acceptance
The status of the safety card must be confirmed after completion of the safety techno-
logy verification. To confirm the data set, enter the checksum of the report in As-
sist CS..
21877787147
9.9
Restoring the delivery state
9.9.1
Prerequisites
Before restoring the delivery state, you must ensure that the system is in idle state and
no dangerous movements can be performed.
No drive safety function is approved in the delivery state of the safety card. The safety
card permanently activates STO.
9.9.2
Procedure
1. Select the menu item "Diagnostics MOVISAFE
®
CS.." in the menu "Diagnostics" in
MOVISUITE
®
. Select the menu item "General". Click the [Restore delivery state]
button.
2. Open the "Assist CS.." parameterization tool and log in.
3. Transfer the data to the device. In the context menu of the axis, select the menu
item "Device → PC" to update the data.
24842532/EN – 04/2018