INFORMATION
If the safe digital output is assigned to a drive safety function via the function assign-
ment, this drive safety function is selected in the case of a system error.
Critical error
In the case of a critical error, the safety card is set to the safe state. All safe digital in-
puts and all safe digital outputs are switched to the safe state. In addition, the drive
safety function STO is executed without delay. The sensor supply for the safe digital
inputs is also switched to the deenergized state. Active safe communication is suspen-
ded.
In addition, the corresponding error code is transferred for the critical error that oc-
curred.
Error messages
If there is an error in the safety card, the inverter indicates that the safety card is re-
porting an error.
Measures for error resolution and more information on causes can be found via the
error status of the safety card.
12.5
Error diagnostics
The error status "Current first error" indicates the first error of the safety card that oc-
curred, along with the associated error code, sub-error code and the error description.
For internal purposes, additional error codes are displayed.
The current first error is the error that occurs after a restart or since the last acknow-
ledgment as the first error with the highest priority.