MOVIDRIVE
®
MD_60A, Absolute Positioning
41
93
DIP encoder
fault
Emergency
stop
With DIP11A option only:
The encoder signals a fault, e.g.
power failure.
•
Connection cable between
the encoder and DIP does
not meet the requirements
(twisted pair, shielded)
•
Cycle frequency too high for
cable length
•
Permitted max. speed/
acceleration of encoder
exceeded
•
Encoder defective
•
Check absolute encoder
connection
•
Check motor leads
•
Set correct cycle frequency
•
Reduce max. traveling
velocity or ramp
•
Fit new absolute encoder
94
EEPROM
checksum
Immediate
shut-off
Inverter electronics disrupted,
possibly due to EMC effect or
fault.
Send the unit in for repair.
95
DIP
plausibility
error
Emergency
stop
With DIP11A option only:
Unable to determine a logical
position.
•
Incorrect encoder type set
•
IPOS travel parameter set
incorrectly
•
Numerator/denominator
factor set incorrectly
•
Zero adjustment performed
•
Encoder defective
•
Set the correct encoder type
•
Check IPOS travel parameter
•
Check traveling velocity
•
Correct numerator/
denominator factor
•
Reset after zero adjustment.
•
Fit new absolute encoder
Error
code
Name
Response
P Possible cause
Action
Summary of Contents for movidrive md_60a
Page 1: ...MOVIDRIVE MD_60A Absolute Positioning Edition 03 2001 Manual 1051 0117 EN...
Page 2: ...SEW EURODRIVE...
Page 4: ...4 MOVIDRIVE MD_60A Absolute Positioning Documentation Safety and warning instructions...
Page 5: ...MOVIDRIVE MD_60A Absolute Positioning 5 2 1 Application fields 18...
Page 27: ...MOVIDRIVE MD_60A Absolute Positioning 27 Scaling 04442AEN Fig 18 Setting the scaling 0 0 I...
Page 33: ...MOVIDRIVE MD_60A Absolute Positioning 33 Jog mode Note 04448AEN Fig 24 Jog mode 0 0 I...
Page 37: ...MOVIDRIVE MD_60A Absolute Positioning 37 Moving clear of limit switches...
Page 39: ...MOVIDRIVE MD_60A Absolute Positioning 39 6 3 Error messages Display List of faults 01038AXX...
Page 42: ...10 2000...
Page 43: ...10 2000...