36
MOVIDRIVE
®
MD_60A, Absolute Positioning
Automatic mode
04451AXX
Fig. 27: Timing diagram of automatic mode
PA1:1 = Enable/rapid stop
(1) = Start jog mode
PA1:2 = Enable/stop
(2) = Position 50000 reached
PA1:11 = Mode selection
(3) = Position 100000 reached
PA1:12 = Mode selection
(4) = Position 75000 reached
PA1:13 = Speed selection
PA1:14 = Ramp selection
n1 = Reduced speed
PA1:8 = Start
n2 = Rapid speed velocity
PA2
= Target position high
n3 = Positioning speed
PA3
= Target position low
PE1:3 = Target position reached
DBØØ = /Brake
n [1/min]
n2
n1
n3
-n3
0
-n1
-n2
PA1:0
PA1:1
PA1:2
PA1:11
PA1:12
PA1:13
PA1:14
PA1:8
PA2
PA3
PE1:3
DBØØ
(1)
(2)
(3)
(4)
0000 hex
C350 hex
0001 hex
86A0 hex
0001 hex
24F8 hex
Summary of Contents for movidrive md_60a
Page 1: ...MOVIDRIVE MD_60A Absolute Positioning Edition 03 2001 Manual 1051 0117 EN...
Page 2: ...SEW EURODRIVE...
Page 4: ...4 MOVIDRIVE MD_60A Absolute Positioning Documentation Safety and warning instructions...
Page 5: ...MOVIDRIVE MD_60A Absolute Positioning 5 2 1 Application fields 18...
Page 27: ...MOVIDRIVE MD_60A Absolute Positioning 27 Scaling 04442AEN Fig 18 Setting the scaling 0 0 I...
Page 33: ...MOVIDRIVE MD_60A Absolute Positioning 33 Jog mode Note 04448AEN Fig 24 Jog mode 0 0 I...
Page 37: ...MOVIDRIVE MD_60A Absolute Positioning 37 Moving clear of limit switches...
Page 39: ...MOVIDRIVE MD_60A Absolute Positioning 39 6 3 Error messages Display List of faults 01038AXX...
Page 42: ...10 2000...
Page 43: ...10 2000...