100
Manual – MOVIDRIVE® MDX60B/61B Communication and Fieldbus Unit Profile
7
Monitoring functions
SEW Unit Profile
Timeout monitoring
is useful for all communciation interfaces. However, it may vary
considerably between the individual bus systems.
Parameters for fieldbus timeout
Value range
Unit
Seconds
Range
0.01 s to 650.00 s in 10-ms steps
Special case
0 or 650.00 = Fieldbus timeout disabled
Factory setting
0.5 s
TIP
With nearly all fieldbus systems (exception: Modbus/TCP and MOVILINK
®
via
RS485 and SBus), the timeout interval (P819 or P883/893) is set automatically by
the controller.
Parameters P819, P883 and P893 only serve as indicators.