Manual – MOVIDRIVE® MDX60B/61B Communication and Fieldbus Unit Profile
5
CANopen profile via CAN
CAN Interfaces of MOVIDRIVE® B
MOVIDRIVE
®
B saves all parameters to the non-volatile memory card; that is, the
settings of the CANopen communication range (CANopen index 0x1000 - 0x1FFF) are
also reset to the last available value once the system is restarted.
The CANopen communication range can be reset to its original settings using the NMT
service "Reset_Communication". If you want to reset all parameters of MOVIDRIVE
®
B,
you can use parameter P802 or write value "1" to index 8594.
5.4.1
Configuring the CANopen interface of MDX B and network management (NMT)
Baud rate and
CANopen slave
address
Parameters P884/P894 are used to set the CAN baud rate. The baud rate can only be
set to 1 Mbaud when the baud rate of the other Sbus is 125 kBaud. The CANopen slave
address can be set using parameters P886/P896. If the CAN baud rate or CANopen
slave address is changed, CAN communication will restart.
Unit states and
NMT services
MOVIDRIVE
®
B untersupports the so-called "Minimum Capability Device". This means
the following states are supported: "pre-operational", "operational" and "stopped" (see
figure below).
TIP
You can check the status of the CANopen slave (NMT status, guarding, identifier, and
mapping of PDOs) of MOVIDRIVE
®
B in the MOVITOOLS
®
MotionStudio context
menu of MOVIDRIVE
®
under [Diagnostics] / [CANopen configuration].
64336AXX
Initialisation
Pre-Operational
Power on
Operational
Stopped
[11]
[12]
[10]
[8]
[7]
[8]
[6]
[6]
[7]