66
Manual – MOVIDRIVE® MDX60B/61B Communication and Fieldbus Unit Profile
5
Other unit functions via CAN interfaces
CAN Interfaces of MOVIDRIVE® B
6. Settings in
MOVITOOLS
®
MotionStudio
The following parameters are important in parameter groups P88x and P89x for
MOVIDRIVE
®
B:
• P880/P890 Protocol SBus 1/2
Only the MOVILINK
®
protocol allows for this synchronization
• P884/P894 SBus baud rate 1/2
All stations on the SBus must be set to the same baud rate. Baud rate, maximum
cable length, and telegrams/time depend on one another.
• P885/P895
See points 1B, 2A, and 4A. The time slice can be synchronized in the MOVILINK
®
protocol via both SBus interfaces. It is important that synchronization messages
are received via only one SBus.
• P887 Synchronization ext. controller 1/2
The time base for all units to be synchronized must be either about 1 ms
(standard for MOVIDRIVE
®
A; P887 = OFF for MOVIDRIVE
®
B) or exactly 1 ms
(P887 = ON, only for MOVIDRIVE
®
B).
12111AEN