92
Manual – MOVIDRIVE® MDX60B/61B Communication and Fieldbus Unit Profile
7
Sequence control
SEW Unit Profile
7.4.5
Control word 2
Control word 2 contains the function bits for the most important drive functions in the
basis control block; the virtual input terminals in the higher-order part. These are freely-
programmable input terminals that are not physically available due to missing hardware
(option cards). In this way, the input terminals are represented on the virtual input
terminals of the fieldbus. Each virtual terminal is assigned to an optional and
physically
unavailable
input terminal. Its functionality can be programmed as required.
Bit Function
Definition
0
Controller inhibit "1" / Enable "0"
Fixed definition
1
Enable "1" / Rapid stop "0"
2
Enable "1" / Stop "0"
3
Hold control
4
Integrator switchover
5
Parameter set switch-over
6
Reset
7
Reserved
8
Virtual terminal 1 = P610 / Binary input DI10
Virtual input terminals
9
Virtual terminal 2 = P611 / Binary input DI11
10 Virtual terminal 3 = P612 / Binary input DI12
11
Virtual terminal 4 = P613 / Binary input DI13
12 Virtual terminal 5 = P614 / Binary input DI14
13 Virtual terminal 6 = P615 / Binary input DI15
14 Virtual terminal 7 = P616 / Binary input DI16
15 Virtual terminal 8 = P617 / Binary input DI17
NOTICE
If both the fieldbus option card and DIO11 are inserted in the drive inverter, the inputs
of the DIO11 option have priority. In this case, the virtual inputs are not evaluated.