Manual – MOVIDRIVE® MDX60B/61B Communication and Fieldbus Unit Profile
97
7
Sequence control
SEW Unit Profile
7.4.10 Fault number and unit status
Unit status
The 7-segment display shows the operating condition of MOVIDRIVE
®
and, in the event
of an error, an error or warning code.
TIP
You find a current list with fault numbers and unit states in the parameter directory
matching the firmware of your units. For more detailed information, refer to the
operating instructions and the MOVIDRIVE
®
MDX60B/61B system manual.
7-segment display
Unit status
(high byte in status word 1)
Meaning
0
0
24 V operation (inverter not ready)
1
1
Controller inhibit active
2
2
No enable
3
3
Standstill current
4
4
Enable
5
5
n-control (speed control)
6
6
M-control (torque control)
7
7
Hold control
8
8
Factory setting
9
9
Limit switch contacted
A
10
Technology option
c
12
IPOS
plus®
reference travel
d
13
Flying start
E
14
Calibrate encoder
F
Fault number is indicated in
the status word
Fault indicator (flashing)
H
The actual unit status is
indicated
Manual operation
t
16
Inverter is waiting for data
U
17
"Safe Stop" active
•
(blinking dot)
-
IPOS
plus®
program is running
Flashing display
-
STOP via DBG60B
1 ... 9
-
RAM defective
WARNING
Incorrect interpretation of display U = "Safe stop" active.
Severe or fatal injuries.
The display U = "Safe stop" active is not safety-related and may not be used as
a safety function!