Manual – MOVIDRIVE® MDX60B/61B Communication and Fieldbus Unit Profile
61
5
Other unit functions via CAN interfaces
CAN Interfaces of MOVIDRIVE® B
5.5.2
Using CAN interfaces in IPOS
plus®
(depending on the profile)
In the IPOS
plus®
positioning and sequence control system integrated in MOVIDRIVE
®
B, you can
• directly access the process data transmitted via SBus using the commands GETSYS
PO data and SETSYS PI data.
Depending on the chosen profile (P880/890), the data are read or written in
CANopen format (low byte first) or in MOVILINK
®
format (high byte first).
• access process and parameter data of other SEW drives connected via CAN using
the MOVILINK
®
command.
Depending on whether MOVILINK
®
or CANopen was set as profile (P880/890), the
MOVILINK
®
structure differs for parameter access.
Set the bus type as follows:
• "5" for access via CAN1 (SBus 1)
• "8" for access via CAN 2 (SBus 2)
TIP
For more information on IPOS
plus®
commands, refer to the "IPOS
plus®
Positioning and
Sequence Control " manual.