96
Manual – MOVIDRIVE® MDX60B/61B Communication and Fieldbus Unit Profile
7
Sequence control
SEW Unit Profile
7.4.9
Status word 3
Status word 3 contains the IPOS
plus®
status messages for positioning tasks in addition
to the condition information in the basic status block. The
unit status
or the
fault number
is indicated in the more significant status byte. Depending on the fault bit, the unit status
is displayed for fault bit = 0 or for problems (fault bit = 1), the error number. The fault bit
is reset by resetting the fault and the current unit status is displayed.
Bit Function
Definition
0
Motor is turning
Fixed definition
1
Inverter ready
2
IPOS reference
3
IPOS in position
4
Brake released
5
Fault/warning
6
Limit switch CW active
7
Limit switch CCW active
8
Fault/warning?
Bit 3 = 1
→
fault number:
01 Overcurrent
02 ...
Bit 3 = 0
→
Unit status:
0x1 Controller inhibit
0x2 ...
Unit status/Fault number
9
10
11
12
13
14
15