34
Operating Instructions – MOVIFIT® FDC
4
MOVIFIT
®
FDC version for wet areas
Mechanical Installation
4.6
MOVIFIT
®
FDC version for wet areas
4.6.1
Installation notes
Observe the following additional notes when installing MOVIFIT
®
FDC for use in wet
areas:
• Make sure to prevent moisture and dirt from entering the unit during installation.
• After electrical installation and during assembly, check for damaged seals and seal-
ing surfaces.
• Check the state of the profile seal in the EBOX when performing maintenance. If
damaged: Consult SEW-EURODRIVE.
• When using the version for wet areas, SEW-EURODRIVE recommends that you
replace the plastic screw plugs delivered as standard with suitable stainless steel
screws (page 110).
• Note the permitted mounting position (page 23).
• Make sure to install the cable with a drip loop; see the following figure:
INFORMATION
SEW-EURODRIVE guarantees that the specially treated surface is free from flaws.
Report any transport damage immediately.
Although the housing surfaces have a high impact resistance, they are to be handled
with care. The corrosion protection can be affected by damages as a result from
improper handling during transport, installation, operation, cleaning, etc. SEW-
EURODRIVE is not liable for such damage.
4234193419
DI03
DI01DI02
DI00
DI04DI05
DI06DI07
DI08DI09
DI10DI11
DI12/DO00
DI13/DO01
DI14/DO02
DI15/DO03
ICE Prog
PLC
L2
A2
L1
A1
USR
NET
CAN
FDO01
FDO00
FF-ST
ATE
RUN/MS
BF/MS
Eng-E
24V_C
MOVIFIT
®
FDC
Summary of Contents for MOVIFIT FDC
Page 2: ...SEW EURODRIVE Driving the world...
Page 137: ...Operating Instructions MOVIFIT FDC 137 Index Y Y adapter 77 0 9 24 V terminals connection 55...
Page 138: ......
Page 139: ......