36
Operating Instructions – MOVIFIT® FDC
4
MOVIFIT
®
FDC version for wet areas
Mechanical Installation
EMC cable glands
Tighten the EMC cable glands optionally supplied by SEW-EURODRIVE to the following
torques:
The cable retention in the cable gland must withstand the following removal force of the
cable from the cable gland:
• Cable with outer diameter > 10 mm:
≥
160 N
• Cable with outer diameter < 10 mm: = 100 N
512772875
Screw fitting
Part number
Size
Tightening torque
EMC cable glands (nickel-plated
brass)
1820 478 3
M16 x 1.5
3.0 Nm to 4.0 Nm (26 – 35 lb.in)
1820 479 1
M20 x 1.5
3.5 Nm to 5.0 Nm (31 – 44 lb.in)
1820 480 5
M25 x 1.5
4.0 Nm to 5.5 Nm (35 – 49 lb.in)
EMC cable glands (stainless
steel)
1821 636 6
M16 x 1.5
3.5 Nm to 4.5 Nm (31 – 40 lb.in)
1821 637 4
M20 x 1.5
5.0 Nm to 6.5 Nm (44 – 57 lb.in)
1821 638 2
M25 x 1.5
6.0 Nm to 7.5 Nm (53 – 66 lb.in)