54
Operating Instructions – MOVIFIT® FDC
5
Standard ABOX "MTA...-S04.-...-00"
Electrical Installation
5.6.4
Terminal assignment
X1: Line terminals (power bus)
WARNING
Electric shock due to dangerous voltages present in the ABOX.
The maintenance switch disconnects only the connected MOVIGEAR
®
and DRC drive
units from the power supply system. Voltage is still present on the X1 terminals of
MOVIFIT
®
FDC. Voltage is still present on the X8 terminals for up to 5 minutes after
having actuated the maintenance switch.
Severe or fatal injuries.
• Switch off the power to MOVIFIT
®
FDC using a suitable external disconnecting
device, and wait at least 5 minutes before opening the wiring space.
3010522635
Line terminal (power bus)
No.
Name
Function
X1.1
1
L1
Supply system phase 1 (IN)
2
Res.
Reserved
X1.2
1
L2
Supply system phase 2 (IN)
2
Res.
Reserved
X1.3
1
L3
Supply system phase 3 (IN)
2
Res.
Reserved
X1.4
1
PE
PE connection (IN)
2
Res.
Reserved
S3
X8
4
3
2
1
14
13
12
11
X31
X30
X20
2
1
12
11
15
1 2 3 4 5 6 7 8
16171819202122
454647
303132
4849505152
3334353637
9
23
53
38
10
24
54
39
11
25
55
40
12
26
56
41
X25
S3
X8
4
3
2
1
14
13
12
11
X31
X30
X20
2
1
12
11
15
1 2 3 4 5
16171819
4546
8
22
7
21
6
20
47
303132
4849505152
3334353637
9
23
53
38
10
24
54
39
11
25
55
40
12
26
56
41
X25
X1.3
X1.4
X1.2
X1.1
1
2
1
2
1
2
1
2
Summary of Contents for MOVIFIT FDC
Page 2: ...SEW EURODRIVE Driving the world...
Page 137: ...Operating Instructions MOVIFIT FDC 137 Index Y Y adapter 77 0 9 24 V terminals connection 55...
Page 138: ......
Page 139: ......