Operating Instructions – MOVIFIT® FDC
85
5
Connection examples
Electrical Installation
Connection example 2:
The SBus master MOVIFIT
®
FDC is located between the SBus slaves.
DIP switch S3 of the master MOVIFIT
®
FDC = "OFF".
INFORMATION
The connection example below applies in combination with the following master
ABOX:
• Standard ABOX "MTA...-S04.-...-00"
4273650443
X = 16
−
Number of connected SNI units
[1] DIP switch S3 for bus termination
[2] DIP switch for bus termination in the slave unit
[3] EMC cable gland
[3]
[3]
SBus-SLAVE 2
SBus-SLAVE X
–
X25
S.
X25
S.
[2]
[2]
MOVIFIT®-FDC
X25
10
9
23
39
38
53
SBus (CAN)
S3
[1]
[3]
[3]
SBus (CAN)
ON
OFF
OFF
[3]
[3]
SBus-SLAVE 1
X25
S.
[2]
SBus (CAN)
ON
IN
OUT
CAN_GND
CAN_GND
CAN_L
CAN_H
CAN_L
CAN_H
IN
OUT
CAN_GND
CAN_GND
CAN_L
CAN_H
CAN_L
CAN_H
IN
OUT
CAN_GND
CAN_GND
CAN_L
CAN_H
CAN_L
CAN_H
IN
OUT
CAN_GND
CAN_GND
CAN_L
CAN_H
CAN_L
CAN_H