100
Operating Instructions – MOVIFIT® FDC
8
Unit diagnostics
Service
8
Service
8.1
Unit diagnostics
8.2
Unit replacement
8.2.1
Notes on replacing units
The MOVIFIT
®
FDC unit allows for a quick unit replacement. The EBOX is equipped
with a replaceable memory card on which all unit data can be stored.
If the EBOX has to be replaced, the plant can be started up again quickly by simply re-
plugging the memory card.
After startup, you have to download the unit data to the memory card.
INFORMATION
The error diagnostics of the MOVIFIT
®
FDC unit is mainly available on the PC/laptop.
You find more detailed information in the "Communication Controller DHR21B/41B
and MOVIFIT
®
FDC with PROFINET IO Fieldbus Interface" manual.
INFORMATION
Observe the following notes when replacing a unit:
•
Before replacing the unit
, make a data backup:
– In MOVITOOLS
®
MotionStudio, right-click the MOVIFIT
®
FDC symbol.
– Choose [Startup] / [Data Management].
– Choose "Upload".
– Next, click the [Start upload] button.
You find more information in the "Communication Controller DHR21B/41B and
MOVIFIT
®
FDC with fieldbus Interface PROFINET IO" manual.
• The MOVIFIT
®
FDC unit must be switched off when you insert the memory card.
• After the replacement, the parameters last saved on the SD card are used.