Operating Instructions – MOVIFIT® FDC
101
8
Unit replacement
Service
8.2.2
Replacing the unit
Proceed as follows to replace the MOVIFIT
®
EBOX:
1. Perform a data backup now if you are not certain whether the current unit parame-
terization is stored on the SD card.
2. De-energize the MOVIFIT
®
FDC unit and wait at least 5 minutes.
3. Loosen the retaining screw and remove the EBOX from the ABOX.
4. Remove the memory card from the previous EBOX.
5. Insert the memory card into the new EBOX.
6. Position the EBOX on the ABOX.
Tighten the retaining screw.
7. Switch on the MOVIFIT
®
FDC unit with the new EBOX.
8. The parameters saved on the card are now available again.
If required, you can change the parameter set or save the changed unit data on the
memory card after startup.
9. For applications with motor encoder or distance encoder, you have to perform a ref-
erence travel.
"PLC" LED:
Flashing green/orange
The data backup of the communication and control unit is restored.
This process can take several minutes.
Do not switch off the MOVIFIT
®
FDC unit during this time!
↓
"PLC" LED:
Flashing green
"IEC Prog" LED:
Lit green
The data of the communication and control unit has been restored.
Boot process is active.
Data backup of the MOVIGEAR
®
and DRC drive units is restored.