Operating Instructions – MOVIFIT® FDC
107
9
Communication and control unit
Technical Data
9.4
Communication and control unit
9.4.1
Binary inputs
9.4.2
Binary outputs
Control card
Performance class
CCU standard
MOVI-PLC
®
standard
CCU advanced
MOVI-PLC
®
advanced
SD memory card
OM
C
41B-T0
(parameterizable)
OM
H
41B-T0
(programmable)
OM
C
41B-T0
to
OM
C
41B-T25
(parameterizable)
OM
H
41B-T0
to
OM
H
41B-T25
(programmable)
Task system
1 x free-running, minimum 10 ms
1 x cyclical 10 – 10000 ms
1 x free-running
8 x cyclical 1 – 10000 ms
Memory
•
Program memory: 2 MB (for user program,
incl. IEC libraries)
•
Data memory: 4 MB (for IEC application)
•
Retain data: 32 kB
•
System variables (retain): 8 kB
•
Program memory: 4 MB (for user program,
incl. IEC libraries)
•
Data memory: 12 MB (for IEC application)
•
Retain data: 32 kB
•
System variables (retain): 8 kB
Engineering
Engineering for all SEW components connected to MOVIFIT
®
FDC is carried out via
•
USB service interface (X51)
•
Ethernet service interface (X52)
•
Ethernet fieldbus interface (X30 / X31 internal) or (X11 / X12 external)
using the MOVITOOLS
®
MotionStudio software with PLC Editor.
Ethernet fieldbus interface
Connection options:
•
Engineering PC
•
Intranet
•
Higher-level controller (see following sections)
Binary inputs
Number of inputs
16
Input type
PLC-compatible according to EN 61131-2 (digital inputs type 1)
R
i
about 3 k
Ω
, sampling cycle
≤
10 ms
Signal level:
DC +13 V – +30 V
DC -3 V – +5 V
"1" = contact closed
"0" = contact open
Sensor supply
DC 24 V to EN 61131-2, interference-voltage proof and short-circuit proof
Rated current
500 mA
Internal voltage drop
max. 2 V
Binary outputs
Number of outputs
4
Output type
PLC-compatible to EN 61131-2, interference-voltage proof and short-circuit-proof
Rated current
500 mA
Leakage current
max. 0.2 mA
Internal voltage drop
max. 2 V
P
i
f
kVA
Hz
n