22
Operating Instructions – MOVIFIT® FDC
3
Type designation MOVIFIT
®
FDC
Unit Structure
3.6.2
ABOX
Nameplate
The following figure shows an example nameplate of the ABOX of MOVIFIT
®
FDC:
Type designation
The following table shows the type designation of the ABOX of MOVIFIT
®
FDC:
3304573579
[1] ABOX status field
[1]
MT A 11 A - 50 3 - S04 3 - M16 - 00 /M11
ABOX option
M11 = Stainless steel mounting rail
ABOX variant
00 = Series
Maintenance switch
M16 = Load discon line protection up to 15 A
M20 = Load discon line protection up to 20 A
Fieldbus
3 =
PROFINET IO, EtherNet/IP, Modbus/TCP
Connection configuration
S04 = Standard ABOX
with terminals and cable bushings
S54 = Hybrid ABOX with M12 for I/Os + bus
and plug connector for MOVIGEAR
®
/ DRC
S64 = Hybrid ABOX with M12 for I/Os,
push-pull RJ45 for bus
and plug connector for MOVIGEAR
®
/ DRC
Supply phases
3 =
3-phase (AC)
Supply voltage
50 = 380 V – 500 V
A =
Version
Series
11 =
Standard (IP65)
13 = Version for wet areas (IP65)
Unit type
A =
ABOX (connection box)
MT = MOVIFIT
®
unit series