Tightening torques
Mechanical Installation
4.5.2
EMC cable glands
Tighten the EMC cable glands optionally included in the delivery with the following tight-
ening torques:
The cable retention in the cable gland must withstand the following removal force of the
cable from the cable gland:
• Cable with outer diameter > 10 mm:
≥
160 N
• Cable with outer diameter < 10 mm: = 100 N
758624523
Screw fitting
Part number
Size
Tightening torque
EMC cable glands (nickel-
plated brass)
1 820 478 3
M16 x 1.5 3.5 to 4.5 Nm (31 – 40 lb.in)
1 820 479 1
M20 x 1.5 5.0 to 6.5 Nm (44 – 57 lb.in)
1 820 480 5
M25 x 1.5 6.0 to 7.5 Nm (53 – 66 lb.in)
EMC cable glands (stainless
steel)
1 821 636 6
M16 x 1.5 3.5 to 4.5 Nm (31 – 40 lb.in)
1 821 637 4
M20 x 1.5 5.0 to 6.5 Nm (44 – 57 lb.in)
1 821 638 2
M25 x 1.5 6.0 to 7.5 Nm (53 – 66 lb.in)