9
Technical data
Interfaces
Operating Instructions – MOVIFIT
®
MC
153
Modbus/TCP interface
Modbus/TCP
Function level
Technology
Automatic baud rate detection
10 MBd/100 MBd
Connection technology
M12, RJ45 (push-pull) and RJ45 plug connector (in ABOX)
Integrated switch
Supports auto-crossing, auto-negotiation
Maximum line length
100 m according to IEEE 802.3
Addressing
4 byte IP address or MAC-ID (00-0F-69-xx-xx-xx)
Can be configured using DHCP server or MOVITOOLS
®
MotionStudio
with version 5.5 and higher,
Default address 192.168.10.4
(depending on S11 DIP switch setting)
Vendor ID
013B
hex
Supported services
FC3, FC16, FC23, FC43
DeviceNet™ interface
DeviceNet™
Function level
Classic
Technology
Protocol variant
Master-slave connection set with polled I/O and bit-strobe I/O
Supported baud rates
500 kBd
250 kBd
125 kBd
Cable length DeviceNet™
See DeviceNet™ specification V 2.0
500 kBd 100 m
250 kBd 250 m
125 kBd 500 m
Bus termination
120 Ω (switch on externally)
Process data configuration
See "MOVIFIT
®
Function Level
Classic..." manual
See "MOVIFIT
®
Function Level
Technology.." manual
Bit-strobe response
Checkback signal of the unit status via bit-strobe I/O data
Address setting
DIP switch
Name of EDS files
SEW_MOVIFIT_Classic.eds
SEW_MOVIFIT_TECH_DNET.eds
Name of icon files
SEW_MOVIFIT_Classic.ico
SEW_MOVIFIT_TECH_DNET.ico
19484828/EN – 01/2015