6
Startup
Description of the DIP switches
Operating Instructions – MOVIFIT
®
MC
117
6.3.4
DIP switch S3
Bus terminating resistor for SBus
• DIP switch S3 = OFF: Bus terminating resistor is
not
active.
• DIP switch S3 = ON: Bus terminating resistor is active.
6.3.5
DIP switch S11
IP parameters for PROFINET IO, EtherNet/IP™ and Modbus/TCP
You can set the IP parameters for PROFINET IO, EtherNet/IP™ and Modbus/TCP at
DIP switches S11/1 – S11/2.
S11
DHCP
DEF IP
res. (OFF)
res. (OFF)
ON
1 2 3 4
9007200422438795
S11/1
"DHCP"
S11/2
"DEF IP"
Status
ON
ON
This combination of settings is not permitted.
ON
OFF
The MOVIFIT
®
unit awaits the IP parameter being assigned by
a DHCP server.
OFF
ON
The IP parameters are set to the following default values when
the DC 24 V voltage is switched on:
IP address:
192.168.10.4
Subnet mask:
255.255.255.0
Default gateway:
1.0.0.0 with EtherNet/IP™
DHCP / Startup Configuration:
Saved IP parameters (DHCP
is deactivated)
OFF
OFF
The IP parameters set in the parameter tree are used. On deliv-
ery, the above-mentioned default values are set.
19484828/EN – 01/2015