Technical data
General technical data
Operating Instructions – MOVIFIT
®
MC
147
9.2
General technical data
General technical data
Connection voltages
V
line
AC 3 x 380 V - 10% – AC 3 x 500 V + 10%
Line frequency
f
line
50 – 60 Hz ± 10%
Input line current:
I
line
Depending on the connected MOVIMOT
®
, the motor protection
switch limits the rated current to 12 A.
Cable length between
MOVIFIT
®
and MOVIMOT
®
max. 30 m (with SEW hybrid cable, type B)
Hybrid cable shielding
Connect inner shield via EMC shield clamps (not for ABOX with
Intercontec circular connector); see chapter "Installation instruc-
tions"
Interference immunity
Meets EN 61800-3
Interference emission
Limit value class C2 according to EN 61800-3
Ambient temperature
-25 to +60 °C (P
Rated
reduction: 3% I
Rated
per K to max. 60 °C)
Climate class
EN 60721-3-3, class 3K3
Storage temperature
-25 to +85 °C (EN 60721-3-3, class 3K3)
Maximum permitted
vibration and impact load
According to EN 50178
Degree of protection
IP65 in accordance with EN 60529 (MOVIFIT
®
housing closed
and all cable bushings and plug connections sealed)
Type of cooling
Natural cooling (DIN 41751)
Overvoltage category
III according to IEC 60664-1 (VDE 0110-1)
Pollution class
2 according to IEC 60664-1 (VDE 0110-1) within the housing
Installation altitude
(see chapters "Electrical Instal-
lation" > "Installation instruc-
tions")
h
h ≤ 1000 m: no derating
h > 1000 m: I
Rated
reduction by 1% per 100 m
h > 2000 m: V
line
derating by AC 6 V per 100 m
h
max
= 4000 m
Weight
EBOX: about 3.1 kg
Standard ABOX: about 4.5 kg
Hybrid ABOX: about 4.8 kg
9.3
Electronics data
General electronics data
Electronics and
sensor supply
24V_C (continuous)
V
IN
= DC 24 V -15%/+20% according to EN 61131-2
I
IN
≤ 500 mA, typically 200 mA (for MOVIFIT
®
electronics) plus up to
1500 mA
(3 x 500 mA) for sensor supply (depending on number and type of con-
nected sensors)
Notice: The following currents must be added to 24V_S and 24V_P
supplies from 24V_C.
19484828/EN – 01/2015