5
Electrical installation
General information
Operating Instructions – MOVIFIT
®
MC
35
5
Electrical installation
5.1
General information
Observe the following notes on electrical installation:
• Observe the general safety notes.
• Strictly observe all instructions referring to the technical data and the permissible
conditions regarding the place of installation.
• Use suitable cable glands for the cables (use reducing adapters if necessary). With
connector plug variants, you must use a suitable mating connector.
• Seal open cable entries with screw plugs.
• Use protective caps to seal plug connectors not in use.
5.2
Installation planning taking EMC aspects into account
INFORMATION
This drive system is not designed for operation on a public low voltage supply system
that supplies residential areas.
MOVIFIT
®
units can cause EMC interference within the permitted limit range accord-
ing to EN 61800-3. In this case, it is recommended for the operator to take suitable
measures.
For detailed information on EMC compliant installation, refer to the SEW publication
Drive Engineering – Practical Implementation, "Electromagnetic Compatibility in Drive
Engineering".
Successful installation of decentralized drives depends on selecting the correct ca-
bles, providing correct grounding and a functioning equipotential bonding.
Always apply the
relevant standards
.
Observe the notes in the following chapters in particular.
19484828/EN – 01/2015