5
Electrical installation
Standard ABOX "MTA...-S01.-...-00"
Operating Instructions – MOVIFIT
®
MC
57
X7, X71, X8, X81, X9, X91: MOVIMOT
®
terminals
1
11
11 12
12 13
13 14
1415
15 16
16
2 3 4 5 6
17
1718
18
7 8
X29
1
11 12 13 14 15 16
2
3
4
5
6
1
2
3
4
11 12 13 14
X1
S3
11
1 2 3 4 5
12 13 14 15
11
1 2 3 4 5
12 13 14 15
31 32 33 34 35
21 22 23 24 25
11
1 2 3 4 5 6 7 8
12 13 14 15 16 17 18
31 32 33 34 35 36 37 38
21 22 23 24 25 26 27 28
X20
X45
X25
X35
X50
1
1 2 3 4 5
2
3
4
1
2
3
4
1 2 3 4 5
X81
1 2 3 4 5
X91
X7
1
2
3
4
X8
X9
X71
1020346251
MOVIMOT
®
terminal (MOVIMOT
®
connection via hybrid cable)
No.
Name
Function
MOVIMOT
®
X7
1
PE
PE connection for MOVIMOT
®
1
1
2
L1_MM1
Phase L1 for MOVIMOT
®
1
3
L2_MM1
Phase L2 for MOVIMOT
®
1
4
L3_MM1
Phase L3 for MOVIMOT
®
1
X71
1
0V24_MM
0V24 reference potential for MOVIMOT
®
1 to 3
2
RS-_MM1
RS485 connection for MOVIMOT
®
1, terminal RS -
3
RS+_MM1
RS485 connection for MOVIMOT
®
1, terminal RS +
4
0V24_MM
0V24 reference potential for MOVIMOT
®
1 to 3
5
+24V_MM
+24 V supply for MOVIMOT
®
1 to 3
X8
1
PE
PE connection for MOVIMOT
®
2
2
2
L1_MM2
Phase L1 for MOVIMOT
®
2
3
L2_MM2
Phase L2 for MOVIMOT
®
2
4
L3_MM2
Phase L3 for MOVIMOT
®
2
X81
1
0V24_MM
0V24 reference potential for MOVIMOT
®
1 to 3
2
RS-_MM2
RS485 connection for MOVIMOT
®
2, terminal RS -
3
RS+_MM2
RS485 connection for MOVIMOT
®
2, terminal RS +
4
0V24_MM
0V24 reference potential for MOVIMOT
®
1 to 3
5
+24V_MM
+24 V supply for MOVIMOT
®
1 to 3
X9
1
PE
PE connection for MOVIMOT
®
3
3
2
L1_MM3
Phase L1 for MOVIMOT
®
3
3
L2_MM3
Phase L2 for MOVIMOT
®
3
4
L3_MM3
Phase L3 for MOVIMOT
®
3
X91
1
0V24_MM
0V24 reference potential for MOVIMOT
®
1 to 3
2
RS-_MM3
RS-485 connection for MOVIMOT
®
3, terminal RS -
3
RS+_MM3
RS485 connection MOVIMOT
®
3, terminal RS +
4
0V24_MM
0V24 reference potential for MOVIMOT
®
1 to 3
5
+24V_MM
+24 V supply for MOVIMOT
®
1 to 3
19484828/EN – 01/2015